_    ___ ___      _                               
/ \ |_ _/ _ \ ___| |_ _ __ ___ __ _ _ __ ___ ___
/ _ \ | | | | / __| __| '__/ _ \/ _` | '_ ` _ \/ __|
/ ___ \ | | |_| \__ \ |_| | | __/ (_| | | | | | \__ \
/_/ \_\___\___/|___/\__|_| \___|\__,_|_| |_| |_|___/
Twitch
Invidious (YT)

Invidious > Channel > Bay Area Retrofit

Trending
Bay Area Retrofit 3150 subscribers    RSS
View channel on YouTube
Videos
Playlists

YT 44 minutes 34 seconds
29 views Shared 7 hours ago
Bay Area Retrofit
PRESENTATION
YT 8 minutes 17 seconds
99 views Shared 2 months ago
Bay Area Retrofit
Earthquake Intensity—What controls the shaking you feel
YT 2 minutes 16 seconds
179 views Shared 8 months ago
Bay Area Retrofit
Homes On Shaking Tables
YT 7 minutes 9 seconds
278 views Shared 11 months ago
Bay Area Retrofit
About Bay Area Retrofit
YT 9 minutes 26 seconds
166 views Shared 1 year ago
Bay Area Retrofit
ABRIDGED EARTHQUAKE RESISTANCE OF STUCCO
YT 7 minutes 26 seconds
343 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300: The Simpson URFP and FRFP Bolting Hardware
YT 10 minutes 44 seconds
198 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300 Retrofits: Stucco Versus Wood Cripple Walls
YT 4 minutes 58 seconds
86 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300 Methods Versus Contractor Methods
YT 2 minutes 49 seconds
87 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300: The Crazy T Block Detail
YT 7 minutes 36 seconds
62 views Shared 1 year ago
Bay Area Retrofit
How to read the tables in FEMA P-1100 and ICC 1300
YT 4 minutes 5 seconds
78 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300 Ignore Additions And Destroys the House
YT 5 minutes 53 seconds
50 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100's and ICC 1300's Ineffective Floor Connectiond
YT 9 minutes 38 seconds
63 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100: Where Did 22 million bucks go?
YT 6 minutes 57 seconds
67 views Shared 1 year ago
Bay Area Retrofit
The Tables in FEMA P-1100 and Standard Plan A
YT 3 minutes 20 seconds
30 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 Contains Terrible Engineering
YT 10 minutes 54 seconds
360 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 And The Simpson FRFP
YT 5 minutes 35 seconds
99 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 Has Hardware That Does Not Exist
YT 3 minutes 40 seconds
86 views Shared 1 year ago
Bay Area Retrofit
Engineering Cripple Wall Retrofits
YT 28 minutes 42 seconds
673 views Shared 1 year ago
Bay Area Retrofit
SAMPLE NO CRIPPLE WALL PROPOSAL
YT 3 minutes 28 seconds
451 views Shared 1 year ago
Bay Area Retrofit
KPIX SPECIAL ON SEISMIC RETROFITTING
YT 2 minutes 22 seconds
342 views Shared 1 year ago
Bay Area Retrofit
How to read your no cripple wall proposal 9-22-21
YT 3 minutes 43 seconds
71 views Shared 1 year ago
Bay Area Retrofit
How to read your cripple wall proposal Howard
YT 2 minutes 26 seconds
195 views Shared 1 year ago
Bay Area Retrofit
How to read your no cripple wall proposal YellowArrow
YT 12 minutes 13 seconds
83 views Shared 1 year ago
Bay Area Retrofit
Apartment Owners
YT 11 minutes 16 seconds
52 views Shared 1 year ago
Bay Area Retrofit
Instruction video
YT 4 minutes 5 seconds
244 views Shared 1 year ago
Bay Area Retrofit
FEMA P-1100 Will Not Protect Your Addition
YT 5 minutes 2 seconds
73 views Shared 2 years ago
Bay Area Retrofit
Geology Of The Hayward Fault Science
YT 3 minutes
489 views Shared 2 years ago
Bay Area Retrofit
Shear Transfer Ties For Proposals
YT 2 minutes 46 seconds
574 views Shared 2 years ago
Bay Area Retrofit
Holdowns For Proposals
YT 4 minutes 59 seconds
459 views Shared 2 years ago
Bay Area Retrofit
Plywood To Bolt Connections
YT 1 minute 3 seconds
198 views Shared 2 years ago
Bay Area Retrofit
Mudsill Plates
YT 59 seconds
1K views Shared 2 years ago
Bay Area Retrofit
BOLT ESSENTIALS
YT 2 minutes 25 seconds
776 views Shared 2 years ago
Bay Area Retrofit
Plywod for proposals
YT 5 minutes 53 seconds
193 views Shared 2 years ago
Bay Area Retrofit
A Terrible FEMA P-1100 Floor To Cripple Wall Connection
YT 2 minutes
264 views Shared 2 years ago
Bay Area Retrofit
Hayward Fault Geology 8-29-2022
YT 3 minutes 12 seconds
45 views Shared 2 years ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300 May Use Inaccurate Earthquake Damage Statistics
YT 7 minutes 3 seconds
269 views Shared 2 years ago
Bay Area Retrofit
Standard Plan A Retrofit Guideline With Problems
YT 5 minutes 2 seconds
160 views Shared 2 years ago
Bay Area Retrofit
FEMA P-1100 Cost Comparison With Standard Plan A
YT 3 minutes 36 seconds
106 views Shared 2 years ago
Bay Area Retrofit
Hilti
YT 1 minute 33 seconds
4.1K views Shared 2 years ago
Bay Area Retrofit
Simpson URFP Installation Guide
YT 4 minutes 1 second
79 views Shared 3 years ago
Bay Area Retrofit
What might happen to your house?
YT 14 minutes 34 seconds
165 views Shared 3 years ago
Bay Area Retrofit
Apartments and Cripple Wall Damage
YT 5 minutes 37 seconds
370 views Shared 3 years ago
Bay Area Retrofit
Old Style Shear Walls: Dagonal Sheathing
YT 5 minutes 10 seconds
31 views Shared 3 years ago
Bay Area Retrofit
Apartment Owners Introduction
YT 2 minutes 52 seconds
250 views Shared 3 years ago
Bay Area Retrofit
Soft Story Hardy Frame
YT 3 minutes 25 seconds
172 views Shared 3 years ago
Bay Area Retrofit
HARDY FRAME Soft Story Retrofit Application
YT 7 minutes 53 seconds
787 views Shared 3 years ago
Bay Area Retrofit
Retrofit Your Home With The Simpson StrongTie Catalog
YT 12 minutes 46 seconds
261 views Shared 3 years ago
Bay Area Retrofit
Engineer It Like a Pro
YT 1 minute 58 seconds
438 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300 neglected the Modified Mercalli Earthquake Scale
YT 5 minutes 22 seconds
53 views Shared 3 years ago
Bay Area Retrofit
Lead Based Paint In Seismic Retrofit Work
YT 3 minutes 51 seconds
213 views Shared 3 years ago
Bay Area Retrofit
Carcinogenic Silica Dust In FEMA P-11 and ICC 1300
YT 5 minutes 3 seconds
554 views Shared 3 years ago
Bay Area Retrofit
Why Get A Permit?
YT 8 minutes 26 seconds
321 views Shared 3 years ago
Bay Area Retrofit
No Cripple Wall Engineering Principles
YT 3 minutes 43 seconds
219 views Shared 3 years ago
Bay Area Retrofit
Earthquake Damage Photos No Cripple Wall
YT 2 minutes 42 seconds
358 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300: Are Plywood Vent Holes Necessary?
YT 13 minutes 18 seconds
270 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100 And ICC 1300 Cutting Floor Joists For Safety
YT 1 minute 1 second
179 views Shared 3 years ago
Bay Area Retrofit
Hillside home damage photos
YT 3 minutes 28 seconds
258 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100 and ICC 1300: The Outrageously Expensive Simpson FRFP
YT 1 minute 18 seconds
93 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100 Recommends Hardware That Does Not Exist
YT 1 minute 57 seconds
101 views Shared 3 years ago
Bay Area Retrofit
FEMA P-1100: The Mysterious Type H Connector.